Small, handy and powerful vector network analyzer is designed for measuring most useful parameters of cable and antenna systems in the range of 100 kHz to 230 MHz. Compared with the other devices the Stick is the State-of-the-Art Antenna & Cable Analyzer. Because it has Key benefits: less size you obtain, less weight you carry, less time you measure.
RigExpert Stick 230 reviews:
Finally more you gain, more you win!
The device is ideal for field use.
Look further on a next tab
Warranty coverage by the RigExpertCare™
RigExpert Stick 230.
Specifications
Frequencyrange: from 0.1 to 230 MHz Frequency input step: 1 kHz Measurements for 25, 50, 75, 100, 150, 200, 300, 450 and 600 Ohm systems SWR measurement range: from 1 to 100 in digital mode, from 1 to 10 in graph modes Range R and X: 0… 10000, -10000… 10000
Operating modes:
SWR, Return loss, R, X, Z, L, C, magnitude and phase angle at one frequency.
SWR chart, 100 points.
Multé mode – for quick testing of a multi-band antenna.
HF output:
Connector type: UHF (SO-239).
Output signal shape: square, from 0.1 to 230 MHz.
Output power: -10 dBm (at a load of 50 Ohms).
Power:
One lithium-ion battery 3.7 V type 18650
When the analyzer is connected to a PC or DC adapter with a USB connector, it receives power from these sources
Interface:
Monochrome electronic paper display with a size of 200 × 200
2 × 3 keys on the waterproof keyboard
English menu and help screens
USB connection to a personal computer
Bluetooth: v.4.2 BLE Single Mode, Class B Dimensions: 185 mm x 40 mm x 33 mm (7.3 inches x 1.6 inches x 1.3 inches) Operating temperature: 0 … 40 ° C (32 … 104 ° F) Weight: 185 g (6.5 ounces) with battery Warranty: 2 years GTIN-13: 4820185420259
RigExpert Stick is made in Ukraine.
* All specifications are subject to change without notice or obligation.
RigExpert Stick 230.
Inside The Box
RigExpert Stick 230 antenna analyzer (with a Li-ion battery type 18650)
quick start guide
neck strap
USB cable
RigExpert Stick 230.
Users Manual
“Every job needs the right tool”
Stick230 is an antenna and cable vector analyzer. The analyzer allows you to measure various parameters of antennas, cables, lines, filters, and many others in the frequency range from 100 kHz to 230 MHz.
The Stick 230 analyzer has a compact size and lightweight, which is great for using the analyzer both in the home and in the field.
The main parameters of the Stick 230 analyzer:
Operating frequency: 100 kHz – 230 MHz
Size: 185 * 40 * 33 mm (7,3 in x 1,6 in x 1,3 in)
Weight: 185 grams (6.5 Oz) (unpacked, with battery installed)
Type of antenna connector: SO-239
Number of Enter Keys: 6
Display: monochrome e-paper, 200 * 200 pixels.
Type of battery used: Li-ion 18650 (included)
PC Connector Type: USB 2.0 Type-C
Charging Port Type: USB Type-C
Bluetooth Availability: Yes, Bluetooth ver. 4.2 BLE Single-mode, Class B
Battery Charge Time: 3 hours.
RF Power: -10 dBm (at 50 Ohm load)
Minimum frequency step: 1 kHz
Operating temperature: 0…40 °C (32…104 °F)
Turning on the analyzer.
The Stick 230 analyzer can be turned on in several ways: – by pressing the key. – when connecting the analyzer to a PC via a USB cable (the analyzer will turn on automatically). – by long-pressing one of the keys : Important! At the same time, the analyzer will turn on and activate the measurement mode to which the pressed key corresponds.
You can turn off the analyzer from any mode by long-pressing the key.
Important!When the analyzer is turned off, its screen does not become blank. The screen always displays the following information:
After turning on the analyzer, using the key a screen with the main menu of the analyzer is available for the user.
In addition to service information, at the top of the screen (battery charge, the indication of connection to a PC, charger, Bluetooth connection), the screen displays 4 main measuring functions of the analyzer: Singe Multé HAM Free The Singe and Multé functions display the measurement result as numbers, while the HAM and Free functions display the measurement results as numbers and charts.
When you press in the Main Menu, 5 information screens will be available.
The first four screen will briefly talk about the main measuring functions of the analyzer (Single, Multé, HAM, Free). By pressing the key, you can switch to the corresponding measurement mode.
On the fifth screen, when you press the key, you will enter the Settings menu.
Single is a measurement of all parameters. The mode is started by pressing the key.
After pressing the key, the measurement will start automatically. This is indicated by a flashing antenna icon located at the top of the screen. You can stop the measurement by pressing once. You can resume the measurement by pressing once.
In Single mode, the analyzer has 5 screens with information.
The first screen displays:
working frequency
SWR value
return loss value
The second screen displays:
working frequency
|Z| value
value of active (R) and reactive (X) resistance (taking into account the sign) for the series mode
The third screen displays:
working frequency
|Z| value
inductance (L) and capacitance (C) value for series mode
Important! Sometimes inductance or capacitance values are displayed with a minus sign. It would seem to be contrary to the laws of physics. But no, in Rig Expert analyzers, the minus sign next to the value indicates how much inductance or capacitance you need to add to the circuit in order to compensate for the reactive component of the impedance.
On the fourth screen are displayed:
working frequency
magnitude
value of active (R) and reactive (X) resistance (taking into account the sign) for parallel mode
The fifth screen displays:
working frequency
phase value
inductance (L) and capacitance (C) value for parallel mode
Screens switch among themselves by pressing keys.
There are two ways to change the value of the operating frequency:
keystrokes and A single press changes the frequency value minimally. If you press and hold the keys, the frequency will change continuously with an accelerated step.
pressing and holding the key for 2 seconds. After that, an information window will appear on the analyzer screen. Press key again. A window will appear on the analyzer screen with the setting of the operating frequency. The keys select the cursor position to change units, tens, hundreds, thousands of kilohertz, and the keys change the value.
A single press of the key saves the change and returns to Single mode. A single press of the key returns to Single mode without saving changes. The help menu is accessible by pressing and holding the key and then selecting the Help mode with the keys.
Multé is a new mode, in which you can quickly assess how well your antenna works on different HAM bands. The result is displayed as stars. The smaller the SWR of the antenna in the range, the more stars.
Table of the dependence of the number of stars on the SWR:
5 – SWR from 1.0 to 1.1
4 – SWR from 1.1 to 1.15
3 – SWR from 1.15 to 1.3
2 – SWR from 1.3 to 1.7
1 – SWR from 1.7 to 3.0
The SWR over 3 analyzer in Multé mode ignores.
If, after scanning, the analyzer did not find a single resonance, then this means that either your antenna has a minimum SWR of more than 3, or the antenna or coaxial cable is damaged.
Restarting this mode is possible by pressing any key except key.
After successful measurement in Multé mode, the following information will be displayed on the analyzer screen:
band
number of stars (out of 5)
minimum value of SWR and the frequency at which this value was found
If there are more than one results detected by the analyzer, then the screens are switched using the keys. When you press thekeys on one of the results screens, the analyzer switches to HAM mode on the same band.
A long press of thekey will bring up the Help menu.
This mode allows you to measure and display the SWR antenna chart on the analyzer screen on one of the fixed HAM radio bands such as:
2.2 km, 630 m, 160 m, 80 m, 60 m, 40 m, 30 m, 20 m, 17 m, 15 m, 12 m, 11 m, 10 m, 6 m, 2 m.
Enabling this mode is possible either from the main menu by pressing the key or when the analyzer is off by a long press of the same key. The measurement will be performed automatically in the range that was used in the previous measurement.
To repeat the measurement, press once. To measure in a cycle, press the key two times at short intervals.A long press of thekey will bring up the Help window.
You can change the measuring range using the keys.
In HAM mode, the SWR icon and the range over which the measurement is carried out are displayed at the top of the screen.
In the center of the screen, a chart of the SWR values for the range is displayed.
The value of the minimum SWR found and the frequency at which this value was found are displayed at the bottom of the screen.
Important! To the left and right of the graph are two vertical stripes. They indicate going out of range. Sometimes the resonance of the antenna may be out of range, but very close to the beginning or end. In such cases, the analyzer will determine the resonance beyond the limits of the ranges.
When you press the or keys the analyzer switches to Free mode with the center frequency of measurement corresponding to the center frequency of the selected range:
You can exit the mode in the main menu by briefly pressing the key.
This is a classic SWR measurement mode with plotting in a user-defined frequency band.
This mode is useful for survey measurement of the antenna in a wide frequency range or for measuring the SWR in a very narrow predetermined area.
In Free mode, the following is displayed on the analyzer screen:
at the top of the screen: the value of the center frequency of the measurement and the width of the measurement band.
in the middle of the screen: SWR chart
at the bottom of the screen: the SWR value under the marker (solid vertical line) and the minimum of the SWR found (dashed vertical line).
There are two ways to set the center of the measurement frequency:
keys. Pressing the key once will change the frequency discretely to a certain value. Pressing and holding the key will cause an accelerated continuous change in frequency.
long press After press, a window will be available with a choice of setting the center frequency, exit or calling Help. Press briefly and enter the frequency setting menu.
The keys select the cursor position to change units, tens, hundreds, thousands of kilohertz, and the keys change the value.
Setting the measurement bandwidth by pressing the keys.
The minimum bandwidth is 10 kHz. A quick double press of the key will cause a measurement in a loop. To stop click key.
To exit the mode, briefly press key.
In order to get to the settings menu, in the Main menu, press and hold the key.
After that, the information window will be available:
Pressing the key will take the analyzer to the Settings menu. Pressing the key will return the analyzer to the Main menu.
Change of settings screens is carried out with keys and change of parameters with keys.
There are currently 10 basic settings available in the Stick 230 analyzer:
Language. Analyzer interface language. The default is English.
Turn on/off Bluetooth (enabled by default). If you do not use the Bluetooth connection of the analyzer with the smartphone, turn off this function. This will save battery power.
Choosing ITU region. The default is 1 region. The choice of region affects the boundaries of predefined ranges. The width of most ranges in each region is different.
Band search. This setting affects the speed worked of the Multé function. There are two meanings: Normal and Deep. In Normal mode, the Multe function is fast, but there is a chance of missing the narrow resonance of the antenna or inaccurate determination of resonance frequency. In Deep mode, the measurement speed increases, but the possibility of mistakes is minimized.
OSL calibration. Disabled by default.
System Z0. Choosing a system impedance value. Available values: 12.5 Ohm, 25 Ohm, 28 Ohm, 37 Ohm, 50 Ohm, 75 Ohm, 100 Ohm, 150 Ohm, 200 Ohm, 300 Ohm, 450 Ohm, 600 Ohm. Default: 50 Ohm. This setting is needed in cases where, for example, when measuring, a broadband transformer with a transformation ratio of 1: 9 is used. In this case, the impedance at the transformer output will be 450 Ohms and for the correct readings of the analyzer, it is necessary to set the system impedance equal to 450 Ohms.
Factory Reset. Reset all analyzer settings to factory defaults. To reset, press and hold the key.
Clear slots. To clear the memory of the saved measurement results, press and hold the key.
Settings are saved automatically when they are changed.
To exit the Settings menu, press the or keys.
Important! The Stick 230 analyzer does not work with the first version of AntScope.
To work with AntScope2 the analyzer does not require the installation of any drivers. Just connect the analyzer to the PC via the USB cable and run the AntScope2 program (the program must be downloaded and installed first). The program should automatically recognize the analyzer and prepare for work.
At the same time, the following information will be displayed in the upper part of the program window:
If the analyzer model does not appear, then this means that the program could not recognize the analyzer. Try reconnecting the analyzer, closing and reopening the program, used a different USB cable.
Important! Using a Bluetooth connection, Stick 230 analyzer operation with AntScope2 is currently not possible. This is due to limited support for the Bluetooth Low Energy protocol used in the analyzer in Windows operating systems.
The Stick 230 analyzer, together with AntScope for Android, works with smartphones and tablets running Android version 6 and higher.
When you connect the analyzer to a smartphone with AntScope for Android, you will see the following information:
The window displays the following information:
analyzer model
serial number
MAC address
Bluetooth version
If the analyzer is successfully connected to the program, the BLE icon will appear at the top of the analyzer screen next to the Bluetooth icon:
If the program could not detect the analyzer, check whether Bluetooth is enabled in the analyzer (1 mode in the Settings menu) and whether Bluetooth is enabled on your smartphone/tablet.
The Stick 230 analyzer is powered by a 18650 Li-ion battery. The analyzer comes with a 2800 mAh battery.
The analyzer can be charged from a PC. According to the specification, when connecting the analyzer to the USB 2.0 connector, the maximum charge current is
0.5 A. When connecting the analyzer to the USB 3.0 standard connector, the maximum charge current is 0.9 A.
The analyzer for charging can be connected to any charger (for phones/tablets) with an output voltage of 5 volts and a current of at least 0.5 A.
The maximum charge current of the analyzer is 1 A.
The time for a full charge of a battery with a capacity of 2800 mAh (from 0 to 100%) is about 3 hours (when using a charger).
During charging, the bottom of the analyzer near the USB connector may become slightly warm. This is not a malfunction.
During charging in the off state, the lightning icon is displayed on the analyzer screen.
During charging, when the analyzer is on, the CHG icon will be displayed at the top of the screen. If the charge occurs with a current of 1 A, then, in this case, the FAST icon is additionally displayed. For example, a screenshot of the screen of the analyzer charged from the charger:
The analyzer battery can also be charged separately. For this, it is necessary to remove it from the analyzer by unscrewing the two screws of the battery cover
and place it in an external charger.
The Stick 230 analyzer is protected against battery polarity reversal. An incorrectly installed battery will not cause damage to the analyzer, and when the charger
is connected, the analyzer will display an error message on the screen.
Important! Do not use other types of batteries! Do not use chargers with a voltage of more than 5 volts! This may damage the analyzer.
In the firmware of the Stick 230 analyzer version 1.7, we added two important tools – user OSL calibration and saving/loading measurement results into the analyzer’s memory.
Now more about OSL calibration.
The Calibration menu is located in the Settings menu under item 7.
If the analyzer has not previously undergone the calibration process, then in this menu we will see only two items: OFF and Calibrate:
The OFF item turns off the calibration, and the Calibrate item starts the calibration process.
Change of items is carried out with the keys and , and the selection of the required item with the key.
After the start analyzer will offer to alternately connect open, short and load calibration standards and press the key.
Remember to prepare the calibration kit in advance!
During the calibration process, the analyzer screen looks something like this:
After completing the process, calibration will be enabled automatically.
On the main screen, a C symbol will appear in the center (which means that OSL calibration is active).
Also, the third item will be available in the Settings menu:
Important!
If you started a new calibration process, but for some reason, this process has not been completed 100% (the device hangs, the battery runs out, the user canceled the process), then the data of the previous calibration will be deleted from the analyzer’s memory, and the ON item will no longer be available.
You must complete all three calibration steps again to activate the OSL calibration.
Click for downloading the latest version of the Antscope2 for your Windows PC.
Click for downloading the latest version of the Antscope2 for your MacOS.
Click for downloading the latest version of the Antscope2 for your Linux OS
Flash Tool for Mac or Windows:
Please download and run the Firmware update tool for Windows.
Please download and run the Firmware update tool for MacOS.
Antscope for iOs & Android
Click for downloading the latest version of the Antscope2 for your iOS device.
Click for downloading the latest version of the Antscope2 for your Android device.
We believe we have the Best prices on these units. If you can find a better price for RigExpert antenna analyzer somewhere please let us know, we will do our best to beat their price. You can order by scrolling to the bottom of this page, if you are a EU based customer please note VAT is not included. VAT registered EU companies do not pay VAT (contact us with your VAT ID code).
We are official distributor for RigExpert and also run full service center. We provide servicing/repairs for all RigExpert products! Contact us for a quote.
Building amplifiers, transmitters, filters or other RF equipment? You will also need these:
Only logged in customers who have purchased this product may leave a review.
Sign-up for our Newsletter
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept All”, you consent to the use of ALL the cookies. However, you may visit "Cookie Settings" to provide a controlled consent.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
cookielawinfo-checkbox-analytics
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checkbox-functional
11 months
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-others
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-performance
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
viewed_cookie_policy
11 months
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
Reviews
There are no reviews yet.